RT-825, 5908312592624
Functions
* the control panel enables programming and monitoring the device operation
* the breaker switch located on the front panel enables switching off the power supply of the whole heating system
* maintaining a preset temperature in accordance with programmed hours and days of the week
* possibility of programming 4 intervals of a required temperature per 24 hours
* 12 program entries: 4 entries concerning the required temperature for working days (Pn-Pt: Monday through Friday); 4 entries concerning the required temperature for Saturday (So: Saturday) and 4 entries concerning the required temperature for Sunday (Nd: Sunday)
* possibility of a quick, manual correction of the currently maintained temperature
* adjustable hysteresis
* 2 temperature sensors: an internal one and an external one
* 3 operation modes of the regulator: operation with the internal temperature sensor; operation with the external temperature sensor; operation with two temperature sensors
* in the mode of operation with two temperature sensors, the external sensor is the limiting one with an adjustable temperature within the range of 15÷50°C
Attention!
The probe is in set with temperature regulator.
Availability date:
Power supply voltage | 230 V AC |
The executive element | relay |
Maximum load current | 16 A |
Contact configuration | 1 × NO |
Separation of the contact | NO |
Temperature regulation range | 5÷60°C |
Hysteresis | 1°C |
Accuracy of setting | 1°C |
Accuracy of measurement | ±1°C |
Time of clock operation | 1 h |
Temperature probe | RT45 |
Reading accuracy | 0,1°C |
Internal temperature sensor | NTC |
Terminal | pluggable terminal blocks 1,5 mm² |
Tightening torque | 0,4 Nm |
Power consumption | 0,8 W |
Working temperature | -10÷50°C |
Dimensions | front: 86×86 mm; gł.22 mm, tył: Ø60; gł.27,5 mm |
Assembly | in a flush-mounted box Ø60 |
Ingress Protection Marking | IP20 |