Functioning
The timer activates and deactivates a given device at preset hours in the following cycles: 24-hour, weekly, working day (Mon-Fri) or weekend (Sat, Sun). Length of pulse: 1s÷99min59s. The relay has two independently programmable, software-switchable control lines connected alternatively receiver (allows you to create, such as the school bell for the control of normal lessons and classes for a separate program summary).
Timer functions
AUTO MODE - work in order to ON-OFF- commands, programmed by the user in the timer memory.
MANUAL MODE - [ON] include permanent contact (pos.1-5) or [OFF] permanent disconnection contact (pos.1-6)
PROGRAM - a program with two lines of the individual entries Hold-ON command, control receivers contact.
ON-OFF COMMAND - entry program, according to which will enable or disable the receiver.
WORKING CYCLE - Adjustable, weekly cycle, in which the receiver is to include a list of orders in accordance with the programmed ON-OFF:
* A single day of the week: Mo, Tu, We, Th, Fr, Sa or Su.
* Working days: Mo, Tu, We, Th, Fr (Monday to Friday);
* Day weekend: Sa, Su (Saturday and Sunday);
* Daily: Mo, Tu, We, Th, Fr, Sa, Su (Monday-Sunday).
AUTOMATIC TIME CHANGE -Changing the time from winter to summer is done automatically at night, on the last Sunday in March at 2.00 (by adding 1 hour to the current time). The change from summer time to winter is done automatically at night, on the last Sunday in October at 3.00 (by subtracting 1 hour from the current time).
DST - Daylight Saving Time - DST Output name (free translation: the mobilization of sunlight). Feature that allows you to disable the automatic time change.
DATE PREVIEW - In AUTO mode, pressing the OK button displays the set date (dd-mm-yy). After 5sek. clock will automatically go to the main.
RESTART - Restarting with the specific processor - necessary in case of suspension of the functions of the clock. Do not delete the date and time entries, and configuration memory.
MEMORY RESET("hard" reset) - delete all previous settings, date, time and entry orders ON / OFF.
Availability date:
Type | programmable shool type |
Power supply voltage | 24÷264 V AC/DC |
The executive element | relay |
Maximum load current | 16 A |
Contact configuration | 1 × NO/NC |
Separation of the contact | YES |
Range of hold time setting | 1s÷99min59s |
Time of clock operation | 6 years |
Battery type | 2032 (lithium) |
Accuracy of the clock's indications | 1 s |
Time error | ±1 s / 24 h |
Accuracy of program time setting | 1 min. |
The number of program memory cells | 120 rozkazów |
Display operation time | NONE |
Accuracy of the hold time setting | 1 s |
Terminal | pluggable terminal blocks 4,0 mm² |
Tightening torque | 0,5 Nm |
Power consumption | 1,5 W |
Working temperature | -20÷50°C |
Dimensions | 2 modules (35 mm) |
Assembly | on rail 35 mm |
Ingress Protection Marking | IP20 |